Difference between revisions of "CV-List"

From wiki-en
Jump to: navigation, search
m (Basic settings)
m (Basic settings)
Line 40: Line 40:
 
a [[CV-Programmer]] which communicates through the Update connector with a PC using the free CV programmer software.<br>
 
a [[CV-Programmer]] which communicates through the Update connector with a PC using the free CV programmer software.<br>
 
<br>
 
<br>
Theire are settings for:<br>
+
There are settings for:<br>
 
<br>
 
<br>
 
* Operation e.g. Lights interconnect, servo operation<br>
 
* Operation e.g. Lights interconnect, servo operation<br>
Line 57: Line 57:
 
<tr><td>CV20</td><td>Activate towing and IR feedback</td></tr>
 
<tr><td>CV20</td><td>Activate towing and IR feedback</td></tr>
 
<tr><td>CV21</td><td>Activating receiver for DC-Car-Booster or DC-Car-PC-Transmitter, Servo operation</td></tr>
 
<tr><td>CV21</td><td>Activating receiver for DC-Car-Booster or DC-Car-PC-Transmitter, Servo operation</td></tr>
<tr><td>CV24</td><td>Beleuchtung permanent Einschalten, Fahrlicht, Blaulichter</td></tr>
+
<tr><td>CV24</td><td>Lights permanent switched on, Headlights, Bluelights</td></tr>
<tr><td>CV27</td><td>Technische Einstellungen Reedschalter, Akkutest, Lichtsensor usw.<br>
+
<tr><td>CV27</td><td>Technical Settings Reed switch, Battey test, Light sensor etc.<br>
0 = Fabrikwert<br>
+
0 = Factory setting<br>
1 = Ausschalten des Akkutests<br>
+
1 = Disable battery test<br>
2 = Ausschalten des Fahrlicht-Sensors<br>
+
2 = Disable light sensor<br>
4 = -Das Blaulicht wird von F5 nach F3 gelegt<br>
+
4 = -The blue light is replaced from F5 to F3<br>
-Der Frontblitzer wird von F6 nach F4 gelegt<br>
+
-Front flashers is replaced from F6 to F4<br>
-F5 und F6 haben damit keine Funktion mehr<br>
+
-F5 and F6 don't have a function anymore<br>
8 = Reedkontakt ausschalten<br>
+
8 = Disable Reed switch<br>
 
<br>
 
<br>
Wenn Sie mehrere Funktionen ausschalten wollen, so müssen die einzelnen Werte addiert werden.<br>
+
When you disable diferent functions you have to add the separate values.<br>
Die Summe wird dann in die CV27 programmiert.<br>
+
The result must be programmed in CV27.<br>
Beispiel: Programmieren Sie den Wert 3 in die CV27, wenn Sie den Akkutest und den Fahrlicht-Sensor ausschalten wollen.</td></tr>
+
Example: Set the value 3 in the CV27, if you want to turn off the battery test and the light sensor.</td></tr>
<tr><td>CV28</td><td>Akkutest Einstellungen Spannungswerte festlegen:<br>
+
<tr><td>CV28</td><td>Define battery test voltage settings:<br>
148 für einen 3,6 Volt LIPO<br>
+
148 3,6 Volt LIPO<br>
132 für einen 3,6 Volt NIC/NIHM (3 Zellen)<br>
+
132 3,6 Volt NIC/NIHM (3 cells)<br>
099 für einen 2,4 Volt NIC/ NIHM (2 Zellen)<br>
+
099 2,4 Volt NIC/ NIHM (2 cells)<br>
049 für einen 1,2 Volt NIC/ NIHM (1 Zelle)<br>
+
049 1,2 Volt NIC/ NIHM (1 cell)<br>
 
</td></tr>
 
</td></tr>
  
<tr><td>CV29</td><td>Lange oder kurze Adresse benutzen<br>
+
<tr><td>CV29</td><td>Usage of long or short address<br>
Adresse unter 127 sind einfach einzustellen.<br>
+
Addresses beneath 127 are simply set.<br>
Adresse über 128 sind mit 3 Parametern festzulgen.<br>
+
Addresses above 127 are set with 3 parameters.<br>
Beachte: genau 128 ist zu vermeiden da die Bitfolge sehr störanfällig ist.<br>
+
Take care: just don't use 128 while these bit setting is sensitive for malfunction.<br>
Um das berechnen zu können gibt es ein Programm.<br>
+
For calculating there is a program.<br>
00 = Kurze DCC Adresse wird verwendet<br>
+
00 = Short DCC Addresses are used<br>
32 = Lange DCC Adresse wird verwendet<br>
+
32 = Long DCC Addresses are used<br>
 
</td></tr>
 
</td></tr>
  
<tr><td>CV48</td><td>Abbremsen durch vorausfahrendes Fahrzeug</td></tr>
+
<tr><td>CV48</td><td>Braking by preceding vehicle</td></tr>
  
<tr><td>CV53</td><td>Beschleunigung in den unteren Fahrstufen</td></tr>
+
<tr><td>CV53</td><td>Acceleration in the lower speed steps</td></tr>
  
<tr><td>CV54</td><td>Beschleunigung in den oberen Fahrstufen</td></tr>
+
<tr><td>CV54</td><td>Acceleration in the upper speed steps</td></tr>
  
<tr><td>CV60</td><td>Lichtausgänge 2,3,4 zum Fahrlicht schalten</td></tr>
+
<tr><td>CV60</td><td>Light outputs 2, 3, 4 for driving light</td></tr>
  
<tr><td>CV69</td><td>Anfahren nach dem Einschalten <br>0 warten auf Befehl oder <br>1 beschleunigen
+
<tr><td>CV69</td><td>Start after power on <br>0 wait for a drive command or <br>1 Accelerate from speed step 1 etc.</td></tr>
ab Fahrstufe 1 usw.</td></tr>
+
  
 
<tr><td>CV98</td><td>Reaktionszeiten bei +2 oder -2 Fahstufen</td></tr>
 
<tr><td>CV98</td><td>Reaktionszeiten bei +2 oder -2 Fahstufen</td></tr>

Revision as of 00:48, 6 February 2015

Die wichtigsten Einstellung beim DC-Car


What are CVs for?

With CV settings you can change the behavior of vehicles as well as the functions.


The values can be changed using:


For some values, multiple functions can be selected.
The individual values are added together.
e.g. CV27 1 battery test switch off + 2 light sensor switched off: enter value = 3

Most updated CV-List DC07 and DC08

Most updated CV-List DC07 and DC08 as PDF


Archives:
Hier you will find old lists for previous decoder types like DC01, DC02, DC03, DC04.
[CV-Liste DC04] [wo-ist-was_2009]

Basic settings


Caveat: If you have changes to many settings and you do not know what to do, first, carried out a RESET though (CV59 = 3) are .>br>
With just a few CV changes the behavior of a DC-Car's is extremely variable.
For this purpose, either a Progset is required which connectes to a digital station, communication is done via IR sensors at the front or
a CV-Programmer which communicates through the Update connector with a PC using the free CV programmer software.

There are settings for:

  • Operation e.g. Lights interconnect, servo operation
  • Behavior, for example, Braking, accelerating, flashing light timing
  • Technical Settings e.g. Battery test, trailer connected
  • Technical settings e.g. Address, DC-Car-Booster, PC-Transmitter



The most important are listed her:

CV1Technical Setting Address up to 127
CV2Slowest speed for speed step 1
CV5Fastet speed for speed step 28
CV19Soft braking and accelerating (from May2013 software)
CV20Activate towing and IR feedback
CV21Activating receiver for DC-Car-Booster or DC-Car-PC-Transmitter, Servo operation
CV24Lights permanent switched on, Headlights, Bluelights
CV27Technical Settings Reed switch, Battey test, Light sensor etc.

0 = Factory setting
1 = Disable battery test
2 = Disable light sensor
4 = -The blue light is replaced from F5 to F3
-Front flashers is replaced from F6 to F4
-F5 and F6 don't have a function anymore
8 = Disable Reed switch

When you disable diferent functions you have to add the separate values.
The result must be programmed in CV27.

Example: Set the value 3 in the CV27, if you want to turn off the battery test and the light sensor.
CV28Define battery test voltage settings:

148 3,6 Volt LIPO
132 3,6 Volt NIC/NIHM (3 cells)
099 2,4 Volt NIC/ NIHM (2 cells)
049 1,2 Volt NIC/ NIHM (1 cell)

CV29Usage of long or short address

Addresses beneath 127 are simply set.
Addresses above 127 are set with 3 parameters.
Take care: just don't use 128 while these bit setting is sensitive for malfunction.
For calculating there is a program.
00 = Short DCC Addresses are used
32 = Long DCC Addresses are used

CV48Braking by preceding vehicle
CV53Acceleration in the lower speed steps
CV54Acceleration in the upper speed steps
CV60Light outputs 2, 3, 4 for driving light
CV69Start after power on
0 wait for a drive command or
1 Accelerate from speed step 1 etc.
CV98Reaktionszeiten bei +2 oder -2 Fahstufen
CV100Fahrzeug-Gattung
0 = Allgemein

1 = LKW kurz
2 = LKW lang
3 = LKW mit Anhänger
4 = Sattelzug
5 = Zugmaschine
6 = Landwirtschaft (Traktor usw.)
7 =
8 = Lieferwagen (Sprinter usw.)
9 = PKW
10 = Einsatzfahrzeug [Sender der Abstandssteuerung beim Halt „AUS“]
11 = Einsatzfahrzeug [Sender der Abstandssteuerung beim Halt „EIN“]
12 =
13 = Müllauto , Post usw.
14 = Bus [Sender der Abstandssteuerung an der Haltestelle „AUS“]

15 = Bus [Sender der Abstandssteuerung an der Haltestelle „EIN“]
CV111Hallsensor aktivieren 1 oder 123 mit Licht 2 beim Halt

Mehrere Werte gemeinsam Nutzen

Gibt es für einen CV mehrere Werte werden diese addiert.
Bit-Werte zusammenrechnen bedeutet:
Wenn bei einer CV mehrere Einstellungen möglich sind, können die "Bits" addiert werden.
z.B. bei CV24 (oder CV59)

  • Lichtsensor aus =1
  • Akkutest aus = 2

Macht zusammen einen Wert 3 dazu noch

  • Reedschalter ingnorieren = 8

ergibt zusammen 11 als Wert für diese CV

Bei dem CV-Programmer mit der Software werden hierzu einfach mehrere Felder markiert. Das Zusammenrechnen macht das Programm.
Gleichzeitig prüft es Bedingungen ab. Das kann zur Folge haben:

  • ein Fahrzeugdecoder ist für diesen CV-Wert nicht geeignet -> Update erforderlich.
  • die CV-Programmer Software ist nicht auf dem neuesten Stand und bietet diese Möglichkeit noch nicht. (Update erforderlich -> Die aktuelle CV-Liste ist der Software immer einige Wochen voraus.)


Beispiele

Bus ohne IR-Abstandsteuerung

Mit Hallsensor und ohne IR-Strahler in der Bushaltestelle. Innenlicht (Licht 2) zum Halt

CV10014
CV111123

Hinweis: Ein zweiter "Bus" reagiert trotzdem auf das Abstandssignal!

Bus mit IR-Abstandsteuerung

Mit Hallsensor und mit IR-Strahler für Halt auf der Straße. Innenlicht (Licht 2) zum Halt

CV10015
CV111123


Gl1-46-7-Antrieb 2.4V

Betrieb mit 2,4 Volt und einer Diode 1N4001 in der Motorleitung

CV215
CV5120
CV4896
CV5350
CV54100

Gl1-46-7-Antrieb 1.2V

Betrieb mit 1,2 Volt

CV225
CV5160
CV4896
CV5325
CV5450

Lipo-Akku mit 1.2V Motor

PKW (Faller®-Umbau) mit Lipoakku 3.6V ohne Dioden, mit permanentem Licht

CV215
CV570
CV24128
CV4896
CV5350
CV54100

Akkutest einstellen

CV270 oder 1
CV283,6 Volt mit einer Diode 130
CV282,4 Volt 100
CV281,2 Volt 50
CV190 Auto fährt mit Fahrstufe 28 weiter Blinkt mit Schweinwerfer und Bremslicht
CV1916 Auto steht und blinkt mit Schweinwerfer und Bremslicht

Die Werte sind am besten experimentel zu ermitteln.
Ist der Wert zu hoch, gehen das Bremslicht und die Scheinwerfer bereits bei Steigungen oder engen Kurven an.
Ist er zu niedrig gibt es keinen "Akkualarm".

CV19=0 : Fahrzeug fährt mit permanenten Licht. Der Akku unterschreitet den Grenzwert. Licht geht aus. Da dadurch die Akkuspannung wieder ansteigt erfolgt keine weitere "Lichtumschaltungen". Das Fahrzeug fährt ohne Licht weiter.

CV19=1 : kann es passieren, das das Fahrzeug anhält und der Akku sich erholt.
Ist die Spannung wieder hoch genug, ruckt das Auto vor.