Difference between revisions of "XT-Modul-Accutest"
m (→DC-Car-XT-Modul) |
m (→Connection Description) |
||
Line 40: | Line 40: | ||
DC voltage of 5V / 500mA via screw terminal block or the mini USB port. <br> | DC voltage of 5V / 500mA via screw terminal block or the mini USB port. <br> | ||
* '''LED indicator''' <br> | * '''LED indicator''' <br> | ||
− | Green LED 5V operating voltage available. Blue LED received valid signal. <br> | + | Green LED: 5V operating voltage available. Blue LED: received valid signal. <br> |
* '''Phototransistor (+ and -)''' <br> | * '''Phototransistor (+ and -)''' <br> | ||
Note: Reverse marked as an LED. <br> | Note: Reverse marked as an LED. <br> | ||
Line 46: | Line 46: | ||
For direct control of a servo on the XT module. | For direct control of a servo on the XT module. | ||
Please pay attention to the correct connection sequence, as these might vary with the different manufacturers. <br> | Please pay attention to the correct connection sequence, as these might vary with the different manufacturers. <br> | ||
+ | |||
=== Setting XT module === | === Setting XT module === | ||
... | ... |
Revision as of 20:53, 20 November 2017
Contents
Basics DC-Car-XT
Default: Evaluation of the battery test
- Sorting out vehicles with an empty battery to reach a charging station in conjunction with a software is fully automatic charging possible)
Other options: see XT Modul
Infrared transmit and receive
The sensor requires a phototransistor.
It can be installed:
- In the guidepost
- In the street as manhole cover
- As a sensor in a stationary vehicle
- hiding in trees, shrubs, buildings
Values for the car decoder
CV25 = 1 Transmitting from the back (infrared LEDs of the rear distance control)
or CV25 = 4 Side or bottom transmitter
CV26 Function of the vehicle with battery empty
CV27 = 2 or 10 battery test turned on
CV28 = 50 (1.2V) or 100 (2.4V) or 130 (3.6V battery)
DC-Car-XT-Modul
- Switching a 3-way servo turn out
- Switching a contact to ground / GND
- Transmitting a freely selectable DC Car Infrared command
You can choose whether the respective function is resetted after a certain time or by triggering a reed contact.
Pin assignment
Connection Description
DC voltage of 5V / 500mA via screw terminal block or the mini USB port.
- LED indicator
Green LED: 5V operating voltage available. Blue LED: received valid signal.
- Phototransistor (+ and -)
Note: Reverse marked as an LED.
- Servo connection
For direct control of a servo on the XT module.
Please pay attention to the correct connection sequence, as these might vary with the different manufacturers.
Setting XT module
...