  111
+
  111 Defines MF4, Hall Sensor features:
 +
  0 = Switches on blue lights and front flashing lights
 +
        After passing the first magnet:
 +
            blue lights and flashing lights ON
 +
        After passing the second magnet:
 +
            blue lights and flashing lights OFF
 +
______________________________________________________________________
 +
  1 = Hall sensor enables the automatic mode (bus, garbage truck, fire, etc)
 +
        When CV100 is set to 10 (queuing emergency vehicles supported from
 +
        software version 01.07.2014)
 +
        After passing the first magnet:
 +
            Blue lights, flashing  lights turned ON
 +
      After passing second magnet:
 +
            Vehicle stops, blue lights remain on flashing lights are switched off
 +
            Stop time = CV103
 +
            Lighting = CV112
 +
        After CV103 time expires:
 +
            Blue lights OFF
 +
            Vehicle drives away
 +
            Departure behavior determined by CV104, 105, 106
 +
&nbsp;
 +
With several emergency vehicles in a queue the command “2e magnet passed” will be
 +
transmitted from first vehicle to followers. After timer has expired a reaction on 2e
 +
magnet will be ignored by followers.
 +
      When CV100 is set to 11 
 +
      After passing the first magnet:
 +
            Blue lights, flashing  lights turned ON
 +
      After passing second magnet:
 +
            Vehicle stops, blue lights remain on flashing lights are switched off
 +
            Stop time = CV103
 +
            Lighting = CV112
 +
      After CV103 time expires:
 +
            Blue lights OFF
 +
            Vehicle drives away
 +
            Departure behavior determined by CV104, 105, 106
 +
      When CV100 is set to 13-15:
 +
      After passing the first magnet:
 +
            Turn signal period = CV109 (If second magnet is not reached in time, auto-off)
 +
            Speed step = CV110
 +
      After passing the second magnet:
 +
            Vehicle stops, front strobes turned off
 +
            Stop time = CV103
 +
            Lighting = CV112
 +
            After CV103 time expires:
 +
            Vehicle departs
 +
            Departure behavior determined by CV104, 105, 106
 +
______________________________________________________________________
 +
122 = Same as 1
 +
______________________________________________________________________
 +
123 = Light 2 is turned on during the stop. Otherwise same behavior as value 1
  
 +
Default: 0
 +
Value:0,1,2,122,123
  
 
[[:Category:CVlist |current list in this WIKI]]<br>
 
[[:Category:CVlist |current list in this WIKI]]<br>

Latest revision as of 23:50, 22 December 2017

111 Defines MF4, Hall Sensor features: 
  0 = Switches on blue lights and front flashing lights 
        After passing the first magnet: 
            blue lights and flashing lights ON 
        After passing the second magnet: 
            blue lights and flashing lights OFF 
______________________________________________________________________ 
  1 = Hall sensor enables the automatic mode (bus, garbage truck, fire, etc) 
       When CV100 is set to 10 (queuing emergency vehicles supported from 
       software version 01.07.2014) 
       After passing the first magnet: 
            Blue lights, flashing  lights turned ON 
      After passing second magnet: 
            Vehicle stops, blue lights remain on flashing lights are switched off 
            Stop time = CV103 
            Lighting = CV112 
       After CV103 time expires: 
            Blue lights OFF 
            Vehicle drives away 
            Departure behavior determined by CV104, 105, 106 
 
With several emergency vehicles in a queue the command “2e magnet passed” will be 
transmitted from first vehicle to followers. After timer has expired a reaction on 2e 
magnet will be ignored by followers. 
      When CV100 is set to 11  
      After passing the first magnet: 
            Blue lights, flashing  lights turned ON 
      After passing second magnet: 
            Vehicle stops, blue lights remain on flashing lights are switched off 
            Stop time = CV103 
            Lighting = CV112 
      After CV103 time expires: 
            Blue lights OFF 
            Vehicle drives away 
            Departure behavior determined by CV104, 105, 106 
      When CV100 is set to 13-15: 
      After passing the first magnet: 
           Turn signal period = CV109 (If second magnet is not reached in time, auto-off) 
           Speed step = CV110 
      After passing the second magnet: 
           Vehicle stops, front strobes turned off 
           Stop time = CV103 
           Lighting = CV112 
           After CV103 time expires: 
           Vehicle departs 
           Departure behavior determined by CV104, 105, 106 
______________________________________________________________________ 
122 = Same as 1 
______________________________________________________________________ 
123 = Light 2 is turned on during the stop. Otherwise same behavior as value 1 
Default: 0
Value:0,1,2,122,123