Difference between revisions of "CV111"
From wiki-en
(Created page with " 111 current list in this WIKI<br> <br> current list as PDF Download<br> File:USA.png File:GB.pn...") |
m |
||
Line 1: | Line 1: | ||
− | 111 | + | 111 Defines MF4, Hall Sensor features: |
+ | 0 = Switches on blue lights and front flashing lights | ||
+ | After passing the first magnet: | ||
+ | blue lights and flashing lights ON | ||
+ | After passing the second magnet: | ||
+ | blue lights and flashing lights OFF | ||
+ | ______________________________________________________________________ | ||
+ | 1 = Hall sensor enables the automatic mode (bus, garbage truck, fire, etc) | ||
+ | When CV100 is set to 10 (queuing emergency vehicles supported from | ||
+ | software version 01.07.2014) | ||
+ | After passing the first magnet: | ||
+ | Blue lights, flashing lights turned ON | ||
+ | After passing second magnet: | ||
+ | Vehicle stops, blue lights remain on flashing lights are switched off | ||
+ | Stop time = CV103 | ||
+ | Lighting = CV112 | ||
+ | After CV103 time expires: | ||
+ | Blue lights OFF | ||
+ | Vehicle drives away | ||
+ | Departure behavior determined by CV104, 105, 106 | ||
+ | With several emergency vehicles in a queue the command “2e magnet passed” will be | ||
+ | transmitted from first vehicle to followers. After timer has expired a reaction on 2e | ||
+ | magnet will be ignored by followers. | ||
+ | |||
+ | When CV100 is set to 11 | ||
+ | After passing the first magnet: | ||
+ | Blue lights, flashing lights turned ON | ||
+ | After passing second magnet: | ||
+ | Vehicle stops, blue lights remain on flashing lights are switched off | ||
+ | Stop time = CV103 | ||
+ | Lighting = CV112 | ||
+ | After CV103 time expires: | ||
+ | Blue lights OFF | ||
+ | Vehicle drives away | ||
+ | Departure behavior determined by CV104, 105, 106 | ||
+ | When CV100 is set to 13-15: | ||
+ | After passing the first magnet: | ||
+ | Turn signal period = CV109 (If second magnet is not reached in time, auto-off) | ||
+ | Speed step = CV110 | ||
+ | After passing the second magnet: | ||
+ | Vehicle stops, front strobes turned off | ||
+ | Stop time = CV103 | ||
+ | Lighting = CV112 | ||
+ | After CV103 time expires: | ||
+ | Vehicle departs | ||
+ | Departure behavior determined by CV104, 105, 106 | ||
+ | ______________________________________________________________________ | ||
+ | 122 = Same as 1 | ||
+ | ______________________________________________________________________ | ||
+ | 123 = Light 2 is turned on during the stop. Otherwise same behavior as value 1 | ||
+ | |||
+ | Default: 0 | ||
+ | Value:0,1,2,122,123 | ||
[[:Category:CVlist |current list in this WIKI]]<br> | [[:Category:CVlist |current list in this WIKI]]<br> |
Revision as of 23:45, 22 December 2017
111 Defines MF4, Hall Sensor features: 0 = Switches on blue lights and front flashing lights After passing the first magnet: blue lights and flashing lights ON After passing the second magnet: blue lights and flashing lights OFF ______________________________________________________________________ 1 = Hall sensor enables the automatic mode (bus, garbage truck, fire, etc) When CV100 is set to 10 (queuing emergency vehicles supported from software version 01.07.2014) After passing the first magnet: Blue lights, flashing lights turned ON After passing second magnet: Vehicle stops, blue lights remain on flashing lights are switched off Stop time = CV103 Lighting = CV112 After CV103 time expires: Blue lights OFF Vehicle drives away Departure behavior determined by CV104, 105, 106
With several emergency vehicles in a queue the command “2e magnet passed” will be transmitted from first vehicle to followers. After timer has expired a reaction on 2e magnet will be ignored by followers. When CV100 is set to 11 After passing the first magnet: Blue lights, flashing lights turned ON After passing second magnet: Vehicle stops, blue lights remain on flashing lights are switched off Stop time = CV103 Lighting = CV112 After CV103 time expires: Blue lights OFF Vehicle drives away Departure behavior determined by CV104, 105, 106 When CV100 is set to 13-15: After passing the first magnet: Turn signal period = CV109 (If second magnet is not reached in time, auto-off) Speed step = CV110 After passing the second magnet: Vehicle stops, front strobes turned off Stop time = CV103 Lighting = CV112 After CV103 time expires: Vehicle departs Departure behavior determined by CV104, 105, 106 ______________________________________________________________________ 122 = Same as 1 ______________________________________________________________________ 123 = Light 2 is turned on during the stop. Otherwise same behavior as value 1
Default: 0 Value:0,1,2,122,123
current list in this WIKI
current list as PDF Download
CV-List DC07/DC08