Difference between revisions of "CV26"
From wiki-en
m (→CV26 accu empty and Watchdog) |
m |
||
Line 6: | Line 6: | ||
<br> | <br> | ||
− | Action if battery is empty | + | Action if battery is empty |
0 = FS28 if battery is empty | 0 = FS28 if battery is empty | ||
Warning light is on | Warning light is on | ||
Line 12: | Line 12: | ||
1 = FS0 (Stop) if battery is empty | 1 = FS0 (Stop) if battery is empty | ||
2 = Instead of warning light the break light flashes | 2 = Instead of warning light the break light flashes | ||
− | 16 = Watchdog, running time limitation to 4 minutes if no control command is received. The vehicle stops with two-way turn signal. (Exhibition or large-scale layout operation) CV160 contains the time in seconds. | + | |
+ | |||
+ | not < 2018 | ||
+ | 16 = Watchdog, running time limitation to 4 minutes if no control command is received. The vehicle stops with two-way turn signal. | ||
+ | (Exhibition or large-scale layout operation) CV160 contains the time in seconds. | ||
32 = Watchdog time * 4 | 32 = Watchdog time * 4 | ||
Latest revision as of 20:10, 21 January 2018
CV26 accu empty and Watchdog
current list in this WIKI
current list as PDF Download
CV-List DC07/DC08
Action if battery is empty 0 = FS28 if battery is empty Warning light is on Battery voltage is reported as good or bad 1 = FS0 (Stop) if battery is empty 2 = Instead of warning light the break light flashes
not < 2018 16 = Watchdog, running time limitation to 4 minutes if no control command is received. The vehicle stops with two-way turn signal. (Exhibition or large-scale layout operation) CV160 contains the time in seconds. 32 = Watchdog time * 4