CV2

From wiki-en
Jump to: navigation, search

CV2 minimum speed.

Default: 20
Value:1-140

Speed at gear 1
All speed values in between are recalculated.
(The value should be lower at least by 28 as the value in CV05)
Recommended is a distance of CV2 to value in CV5 of at least 80.
This ensures the proper operation of the distance control !
Please correct the maximum speed first, if the distance is less than 80.
This can be done by insertion of one ore more diodes at the motor wiring.
CV5 remains unchanged.


Print   Pdf.png CV-List_DC07_and_DC08